InfrastructureTek
InfrastructureTek makes it easy to monitor the health of concrete structures—remotely and cost efficiently
In an exclusive partnership with the Swiss-German company, Infrasolute, InfrastructureTek brings to the US market structural monitoring sensors that provide “eyes” in the concrete. This innovative wireless sensor solution enables preventive and sustainable online monitoring of buildings and infrastructure.
Once placed inside concrete next to the reinforcing steel, our technology assesses its condition and transmits real-time readings for a lifetime of up to 80 years. It uses a patented technology that requires no external energy (battery, power supply) and has been battle-tested across Europe in more than 100 completed projects over the past 15 years.
Traditional condition assessments are labor intensive with limited success in detecting early corrosion. You may not know there’s a problem until it’s become obvious, costly, or worse. There is an order of magnitude increase in rehabilitation costs between early and late stage detection. InfrastructureTek provides the structural monitoring data necessary to detect corrosion and moisture issues while they’re relatively inexpensive to fix.
Our core sensor technology: CorroDec®2G
Wireless and wire-free
Non-destructive sensor (NDT) installation, requiring minimum drilling via a core hole when retrofitting.
No external power required
Energy is induced from the outside (unique in the field) via a fixed gateway or handheld reader.
Real-time data collection
Key parameters are continuously measured and recorded by the sensors, reducing physical inspections and repair & maintenance costs.
Documentation
Itek Downloadable Brochure
Durability Analysis of the Sensors
Structural Health Monitoring Market Research
global-structural-health-monitoring-market-forecast-2032.pdf
Humidity Sensor Report
FAQs
Can I integrate the data into my existing monitoring system(s)?
Yes, it is possible to integrate into third-party systems, allowing for monitoring sensors from different manufacturers in one place or using one software solution. The data can be integrated via common interfaces, such as through iFrames into other systems, enriching BIM models with live sensor data, for example.
Where were the sensors developed and where are they produced?
The sensors were developed in collaboration with Fraunhofer IMS in Germany. They are also manufactured in Germany, highlighting the quality hallmark of “Made in Germany.”
How is it ensured that the technology remains up-to-date even after, for example, 20 years?
RFID technology is innovative, mature, and durable. The reading of installed sensors can only be done using RFID. The technology on the exterior, such as in the handheld reader and the installed gateways, is always accessible and can be updated as needed. This ensures that data retrieval can be guaranteed in the future.
In what types of structures can the sensors be used?
The sensors can be deployed in any structure where reinforced concrete is utilized. As a result, the sensors are installed in underground parking garages, bridges, port facilities, facades, floor slabs, basement rooms, foundations, wind turbines, insulation, tunnels, retaining walls, and many other objects.
How much do these cost?
We are happy to assist you with your project plans and provide a complimentary monitoring concept for each object. Prices are available upon request, and we recommend considering the prices in conjunction with a specific project plan as part of a comprehensive concept.
Who can install the sensors?
Installation can be provided either by the manufacturer/seller of the sensors or done independently after training provided.
What is the exact material of the sensors (including wires)?
The material of the sensor bodies is a robust hard plastic manufactured by injection molding. The sensors are encapsulated with epoxy resin, and there is a granular layer on top for better adhesion to the concrete. The moisture sensor measures between two stainless steel rings. The wires on the corrosion sensor mimic the rebar using S235JR+AR steel. Through various tests, this wire was chosen for its appropriate material properties and thicknesses.
Important
This is an early warning system that indicates the progression of corrosive activities and informs of their speed so that we can receive information and act efficiently. The aim is not to measure the condition of the reinforcement but to warn of a danger to the reinforcement.
What is the maximum allowable depth for sensor installation?
The standard installation depth for moisture or corrosion sensors is limited to 12 in / 30 cm. However, it is possible to achieve a depth of over 328 ft / 100 meters in concrete by using an extended antenna. With the extended antenna setup, the reading unit and the measuring unit are housed in two separate enclosures and connected with a permanent cable link. This allows, for example, measuring at water level in a shipyard while conducting readings from the top of the quay wall. Besides increasing the installation depth, the extended antenna setup can also be utilized to establish reading points, enabling efficient online monitoring with a gateway.
What happens if a sensor fails?
In the rare event that a sensor completely embedded in concrete fails to function, which occurs with a frequency of less than 0.01% due to stringent manufacturing quality standards and thorough sensor-specific quality assurance, a secondary sensor is typically installed near the original sensor using core drilling. The non-functional sensor remains in place as its failure does not compromise or damage the structure.
What is the required depth for sensor installation?
To prevent microcracks and structural weakening, sensors must have a minimum coverage of 5/8 in / 1.5 cm. In areas without direct load impact (such as vertical mounting in columns), a coverage of 3/8 in / 1.0 cm is sufficient. The material used for covering can be chosen according to the specific requirements of the project.
How do I, as a construction client/engineer, access the sensor data?
The data is transmitted directly to the cloud immediately after reading, allowing for immediate access even while on-site at the location. All that’s required is access to InfrastructureTek’s online software, which is provided upon sensor delivery/installation.
How durable are the sensors?
The sensors are highly suitable for construction sites and have been specifically designed to withstand high levels of stress. Various tests regarding durability, load capacity, and robustness were conducted beforehand, and the results were documented in a separate report.
What factors influence the reading range?
Factor | Influence Level |
---|---|
Steel reinforcement (connection with wire tie) | Low |
Steel reinforcement (welded connection) | High |
Operation underwater | Moderate |
Operation under metal-coated sealing | Very High |
Operation near another RFID Reader | Very High |
Embedded in concrete | None |
How frequently is the data read?
When data is manually retrieved using a handheld reader, it is often done in conjunction with physical and visual inspections of the structure. The frequency of data retrieval depends on the number of manual readings or on-site visits. On the other hand, the gateway continuously transmits data. This means that the data retrieval interval can be customized to suit the client’s needs. It is possible to transmit data daily, hourly, or even every 15 minutes. For more information see our readers and software page.
The gateway can be directly connected to an existing power source, supplied with a long-lasting battery, or operate autonomously via solar panel.
How many sensors do I need for a structure?
The determination of the required number of sensors does not have a one-size-fits-all answer and is determined on a project-by-project basis. Each structure embodies its unique history, accompanied by individual weaknesses and risk factors.
The economic viability of sensor deployment requires a tailored analysis of each project. The goal is to cover the majority of potential risks with minimal effort. Therefore, positioning sensors at structurally critical points, low points, water drainage areas, seals, and road transitions proves to be of crucial importance. Additionally, the existing damage history of the structure and the applied repair principle play a significant role.
A premature determination, such as assuming 10 sensors per 100 square meters, would be too superficial given this complexity.
How close to the rebar should the sensors be installed?
There are no specific guidelines for this. It depends on the engineers’ choice of when to trigger the early warning. Some engineers place the corrosion sensor so that the lowest level of the corrosion wire is precisely at the level of the reinforcement to know when corrosion started at that level. However, this does not align with our philosophy of the early warning system. Therefore, the sensor is typically placed directly above the reinforcement, providing information above it. Some prefer to install the sensor as close to the surface as possible to detect trends early.
What occurs if the sensor wire on the corrosion sensor corrodes?
When the sensor wire corrodes, it is immediately detected during the reading process. With continuous 24/7 monitoring through gateways, proactive alerts are triggered. Because each sensor comprises two wire layers, the advancement of corrosion towards the second wire layer can be monitored. However, once a sensor wire corrodes, it cannot revert to its initial state. It is advisable to conduct a thorough analysis of the location and component using additional diagnostic procedures following wire layer corrosion and establish a focal point for future inspections.
What is measured exactly with the moisture sensor?
The moisture sensor measures both the temperature in the concrete and the conductivity between the two outer stainless steel rings. The conductivity value is referenced to the surrounding material and the temperature value through the software, resulting in a moisture value in percentage.
Note
Our philosophy is not to be the best and most precise measuring system. We aim to provide a simple and early indication that the moisture level is abnormal and anomalies are visible, allowing for early action before damage becomes visible or expands.
Does the moisture/humidity sensor need calibration prior to installation, or at any point during its service life?
The moisture sensor is tested for functionality in Germany and does not require further calibration. The measurement values are referenced in the software. There are scientific and practical approaches here: Scientifically, the sensor is referenced in the software to the surrounding material in which it is installed, and the software is adjusted accordingly for the most accurate moisture measurement. However, in practice, it is crucial for the moisture sensor’s purposes to detect trends and observe drying or moisture increases. Therefore, the development of moisture trends is more important than knowing whether there is 1.925% or 2.0123% moisture in the structure. Hence, there is the option to adjust the software to the surrounding material, but the trends and early indication of abnormalities are crucial.